My power controller is actually a Hipotronics model 100 HVT high voltage dielectric test set controll box. My dad used it to test bucket trucks when the high voltage transformer started to leak oil. They bought a whole new test set and he brought the controll box home thinking he may have a use for it someday. That was years ago, and now it is supplying power to my high voltage experiments. It is based off what I think is a 5 kVA, 0 - 140V variac (the original transformer was 50KV/100KV, 100mA/50mA). Besides the variac, the mains are breakered through two 50A breakers, one hot and one neutral. There is an overload breaker, and a safety interlock. The contactor can only be activated when the variac is at zero volts via a micro-switch mounted on the variac. There are two panel meters. One is a three-range 100KV voltage meter and the other is a three range 100mA meter. I only have the probe for the volt meter unfortunately. It is a capacitavely coupled type with BNC connectors.